Automatic Aerosol Fire Extinguisher

Automatic Aerosol Fire Extinguisher

Application:Industrial, Indoor, Electric Power Transmission, Outdoor
Rated Current:1 A
Rated Voltage:12 V
Brand Name:QHECO
IP Level:IP66
Product Type:Hot Aerosol Fire Extinguishing Device
Operating Temperature Range:-50℃ to +90℃
Service Life:10 Years
Extinguishing Density:100g Per Cubic Meter
Nozzle Design:Dual Nozzle Structure
Activation Method:Automatic Temperature Activated / Wire Triggered
Casing Surface Temperature:≤200℃
Oxidizer Composition:Sr(NO3)2 60 Percent KNO3 20 Percent
Core Feature:No Residue, Environmental Protection, Pressure-free Storage
Installation Method:3M Adhesive / DIN Rail Mount
Send Inquiry
Description

🔥 Automatic Aerosol Fire Extinguishing Device - Product Page Content


SEO Meta Information

Title Tag:
Automatic Aerosol Fire Extinguisher | CE Certified | 1.6m³ Protection | OEM Available

Meta Description:
Compact automatic aerosol fire extinguishing device for electrical cabinets, battery boxes & enclosures. CE certified, 10-year lifespan, maintenance-free. Thermal activation ≥170°C. Get quote today!


Hero Section - Product Title & Tagline

Automatic Aerosol Fire Extinguishing Device

Compact. Self-Activating. Zero Maintenance.

Instant Fire Protection for Electrical Cabinets, Battery Boxes & Enclosed Spaces


Key Selling Points (Bullet Points)

✅ Fully Automatic Activation - Thermally triggered at ≥170°C; no wiring or external power required
✅ Rapid Fire Suppression - Extinguishes fire in ≤10 seconds with ≤5s spray duration
✅ Compact & Lightweight - Space-saving design fits inside electrical panels, battery boxes, and small enclosures
✅ Non-Pressurized Storage - Solid-state agent, no cylinder leakage or explosion risk; safe for transport and storage
✅ Eco-Friendly Agent - Zero ozone depletion (ODP=0), zero global warming potential (GWP=0)
✅ 10-Year Service Life - Maintenance-free operation with long-term reliability
✅ CE Certified - Compliant with European safety standards for fire suppression systems
✅ OEM & Customization Available - Private labeling, custom housing colors, and tailored specifications supported


Product Overview

Protect your critical electrical equipment, battery systems, and enclosed machinery with our Automatic Aerosol Fire Extinguishing Device. Engineered for small, confined spaces, this compact unit delivers fast, automatic fire suppression without the need for pressurized cylinders, complex piping, or external power sources.

When temperatures inside your protected enclosure exceed 170°C, the device activates automatically - releasing a dense cloud of ultra-fine potassium-based aerosol particles that interrupt the fire's chemical chain reaction at the molecular level. Fires are suppressed in ≤10 seconds, minimizing damage to valuable equipment and preventing fire spread.

Ideal for electrical distribution cabinets, control panels, battery storage boxes, server racks, vehicle engine compartments, and marine equipment rooms, this device offers a cost-effective, install-and-forget fire safety solution.


Technical Specifications

Parameter Specification
Product Name Automatic Aerosol Fire Extinguishing Device
Protection Space ≤ 1.6 m³
Spray Duration ≤ 5 seconds
Extinguishing Time ≤ 10 seconds
Extinguishing Density 100 g/m³
Activation Mode Thermal (≥ 170°C) / Optional electric trigger
Operating Temperature -50°C to +95°C
Agent Type Condensed potassium aerosol (solid-to-aerosol)
Storage State Non-pressurized solid compound
Service Life 10 years (maintenance-free)
Surface Temp After Discharge < 200°C
Certifications CE Marking
Housing Material High-temperature resistant polymer
Dimensions Compact form factor (customizable)
Weight Lightweight (model dependent)

How It Works

1. Fire Detection

When a fire starts inside the protected enclosure, the internal temperature rises rapidly. The device's thermal sensor detects heat exceeding 170°C and triggers activation automatically.

2. Aerosol Generation

The solid chemical compound inside the device undergoes a controlled exothermic reaction, converting into ultra-fine aerosol particles (primarily potassium compounds) and inert gases.

3. Fire Suppression

The aerosol floods the enclosure within seconds, delivering dual-action suppression:

Chemical Inhibition: Potassium radicals interrupt the fire's combustion chain reaction

Physical Cooling: Aerosol particles absorb heat energy, rapidly lowering temperature

4. Fire Extinguished

The fire is suppressed in ≤10 seconds, leaving minimal residue and no corrosive damage to electrical components when used correctly in enclosed spaces.


Applications & Use Cases

⚡ Electrical & Power Systems

Electrical distribution cabinets & switchboards

Control panels & PLC enclosures

Circuit breaker boxes & meter cabinets

UPS battery cabinets & inverter enclosures

PV combiner boxes & solar power equipment

🔋 Energy Storage & Batteries

Battery storage cabinets & ESS containers

EV battery packs & charging stations

E-bike/e-scooter battery compartments

Power tool battery boxes

🚗 Vehicles & Transportation

Car & SUV engine compartments

RV, bus & truck electrical bays

Marine engine rooms & ship cabins

Railway signal equipment boxes

🖥️ IT & Telecommunications

Server racks & data center cabinets

Network switches & communication base stations

CCTV control boxes & IoT enclosures

🏭 Industrial Equipment

CNC machine control cabinets

Generator & compressor enclosures

Automation machinery panels

Cable trenches & junction boxes


Why Choose Aerosol Over Traditional Extinguishers?

Feature Aerosol Device CO₂ System Dry Powder
Storage Pressure Non-pressurized (safe) High pressure High pressure
Installation Simple, no piping Requires piping & nozzles Manual operation
Power Requirement None (thermal) Electrical None
Residue Minimal, non-corrosive None Heavy, damaging
Maintenance 10 years, none Annual inspections Regular refills
Space Needed Very compact Cylinder + piping Bulky
Cost Low High Medium

Installation Guide

Step 1: Choose Mounting Location

Install the device inside the protected enclosure, centrally positioned for optimal aerosol distribution. Ensure the spray nozzle faces the area of highest fire risk.

Step 2: Mount the Device

Two mounting options available:

DIN Rail Mounting - Clip onto standard 35mm DIN rail (ideal for electrical cabinets)

Adhesive / Screw Mounting - Attach to flat internal surfaces using screws or industrial adhesive

Step 3: Verify Clearance

Maintain minimum clearance around the spray nozzle to ensure unobstructed aerosol discharge. Do not cover the device with cables or equipment.

Step 4: No Wiring Needed (Thermal Model)

For thermal activation models, no electrical connection is required. The device is fully autonomous and ready to protect immediately after installation.

⚠️ Safety Notice: After discharge, do not touch the device casing immediately. Wait until the surface temperature has cooled below 50°C before handling or replacement.


Certifications & Compliance

✅ CE Marking - European Conformity

✅ EN 15276 - Fixed aerosol fire extinguishing systems (compliant design)

✅ RoHS - Restricted hazardous substances compliant

✅ ISO 9001 - Quality management system (factory certified)


Packaging & Shipping

Item Details
Packaging Individual box with foam protection; bulk carton for wholesale
MOQ 1 unit (sample) / 100 units (bulk)
Lead Time 7–15 days for standard orders; 25–35 days for OEM/custom
Shipping Express (DHL/FedEx/UPS), Air Freight, Sea Freight
Payment Terms T/T, L/C, PayPal, Western Union

Frequently Asked Questions (FAQ)

Q1: Does this device require electricity to work?
No. The standard model uses thermal activation (≥170°C) and operates completely without external power. Electric-trigger models are available upon request for integration with fire alarm systems.

Q2: Will the aerosol damage my electrical equipment?
When used in properly enclosed spaces (≤1.6 m³), the aerosol leaves minimal, non-corrosive residue. For precision optical instruments or unsealed sensitive electronics, consult our technical team for suitability assessment.

Q3: How do I know if the device has been activated?
After activation, the device casing will be hot (>150°C) and the blue thermal leads will show burn marks. The protected enclosure may contain light aerosol haze. Replace the unit immediately after discharge.

Q4: Can I install multiple units for larger spaces?
Yes. For spaces larger than 1.6 m³, install multiple devices proportionally based on volume. Use the formula: Total Agent (g) = Volume (m³) × 100 g/m³.

Q5: Is OEM/private labeling available?
Absolutely. We offer full OEM/ODM services including custom branding, housing colors, packaging design, and specification tuning. Contact us for MOQ and pricing.

Q6: What is the shelf life if not installed?
The device has a 10-year service life from the manufacturing date when stored in original packaging under normal conditions (-20°C to +50°C, dry environment).

Hot Tags: automatic aerosol fire extinguisher, China automatic aerosol fire extinguisher manufacturers, factory

Send Inquiry